Related Experiment Video
Updated: May 30, 2026

An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Fast diffusion-weighted steady state free precession imaging of in vivo knee cartilage
O Bieri1, C Ganter, G H Welsch
1Division of Radiological Physics, Department of Medical Radiology, University of Basel Hospital, Basel, Switzerland. oliver.bieri@unibas.ch
Abstract:
Quantification of molecular diffusion with steady state free precession (SSFP) is complicated by the fact that diffusion effects accumulate over several repetition times (TR) leading to complex signal dependencies on transverse and longitudinal magnetization paths. This issue is commonly addressed by setting TR > T(2), yielding strong attenuation of all higher modes, except of the shortest ones. As a result, signal attenuation from diffusion becomes T(2) independent but signal-to-noise ratio (SNR) and sequence efficiency are remarkably poor. In this work, we present a new approach for fast in vivo steady state free precession diffusion-weighted imaging of cartilage with TR << T(2) offering a considerable increase in signal-to-noise ratio and sequence efficiency. At a first glance, prominent coupling between magnetization paths seems to complicate quantification issues in this limit, however, it is observed that diffusion effects become rather T(2) (ΔD ≈ 1/10 ΔT(2)) but not T(1) independent (ΔD ≈ 1/2 ΔT(1)) for low flip angles α ≈ 10 - 15°. As a result, fast high-resolution (0.35 × 0.35 - 0.50 × 0.50 mm(2) in-plane resolution) quantitative diffusion-weighted imaging of human articular cartilage is demonstrated at 3.0 T in a clinical setup using estimated T(1) and T(2) or a combination of measured T(1) and estimated T(2) values.
Related Concept Videos
Magnetic Resonance Imaging
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Imaging Studies IV: Magnetic Resonance Imaging
