Characterization of imaging performance in differential phase contrast CT compared with the conventional CT--noise
Xiangyang Tang1, Yi Yang, Shaojie Tang
1Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Drive, C-5018, Atlanta, Georgia 30322, USA. xiangyang.tang@emory.edu
Purpose:
The differential phase contrast CT is emerging as a new technology to improve the contrast sensitivity of the conventional CT. Via system analysis, modeling, and computer simulation, the authors study the noise power spectrum (NPS)--an imaging performance indicator-of the differential phase contrast CT and compare it with that of the conventional CT.
Methods:
The differential phase contrast CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated with Fourier analysis and Fresnel analysis. To avoid any interference caused by scatter and beam hardening, a monochromatic x-ray source (30 keV) is assumed, which irradiates the object to be imaged by 360 degrees so that no weighting scheme is needed. A 20-fold up-sampling is assumed to simulate x-ray beam's propagation through the gratings Gl and G2 with periods 8 and 4 microm, respectively, while the intergrating distance is 193.6 mm (1/16 of the Tabolt distance). The dimension of the detector cell for data acquisition ranges from 32 x 32 to 128 x 128 microm2, while the field of view in data acquisition is 40.96 x 40.96 mm2. A uniform water phantom with a diameter 37.68 mm is employed to study the NPS, with its complex refraction coefficient n = 1 - delta + ibeta = 1 - 2.5604 x 10(-7) + i1.2353 x 10(-10). The x-ray flux ranges from 10(6) to 10(8) photon/cm2.projection and observes the Poisson distribution, which is consistent with that of micro-CT in preclinical applications. The image matrix of reconstructed water phantom is 1280 x 1280, and a total of 180 regions at 128 x 128 matrix are used for NPS calculation via 2D Fourier Transform in which adequate zero padding is applied to avoid aliasing.
Results:
The preliminary data show that the differential phase contrast CT manifests its NPS with a l/|k| trait, while the distribution of the conventional CTs NPS observes |k|. This accounts for the significant difference in their noise granularity and the differential phase contrast CTs substantial advantage in noise over the conventional CT, particularly, in the situations where the detector cell size for data acquisition is smaller than 100 microm.
Conclusions:
The differential phase contrast CT detects the projection of refractive coefficient's derivative and uses the Hilbert filter for image reconstruction, which leads to the radical difference in its NPS and the advantage in noise in comparison to that of the conventional CT.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)