Related Experiment Video
Updated: May 30, 2026

Tissue-simulating Phantoms for Assessing Potential Near-infrared Fluorescence Imaging Applications in Breast Cancer Surgery
Published on: September 19, 2014
Quantitative assessment of nipple perfusion with near-infrared fluorescence imaging
Yoshitomo Ashitate1, Bernard T Lee, Long H Ngo
1Division of Hematology/Oncology, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Abstract:
Preserving the nipple-areolar complex with a nipple-sparing mastectomy improves cosmesis compared with skin-sparing mastectomy. However, complications such as necrosis of the nipple-areolar complex significantly affect cosmetic outcome. Many factors influence nipple-areolar perfusion, and no consensus currently exists on optimal incisional choice. This study evaluates 2 nipple-sparing mastectomy incision models using near-infrared fluorescence to assess perfusion quantitatively. The periareolar and radial incisions were compared with 2 control models in Yorkshire pigs (N = 6). Methylene blue and indocyanine green were injected intravenously, and near-infrared fluorescence images were recorded at 3 time points: before surgery, immediately after (0 hour), and 3 days postoperatively. Contrast-to-background ratio was used to assess perfusion. At 72 hours, radial incisions showed a statistically significantly higher perfusion compared with periareolar incisions (P < 0.05). Based on our findings, radial incisions for nipple-sparing mastectomy may be preferable due to higher perfusion; however, clinical trials are necessary for further assessment.

