Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Bones of the Upper Limb: Radius01:09

Bones of the Upper Limb: Radius

The radius is longer of the two bones that make up the human antebrachium or forearm. At the proximal end, the radius articulates with the capitulum of the humerus and the radial notch of the ulna to form the elbow joint. At the distal end, the radius articulates with the ulna via the ulnar notch, forming the distal radioulnar joint. Distally, the radius also attaches to the carpal wrist bones (scaphoid and lunate) to form the radiocarpal joint.
The radius has a nail-shaped head, and a short...
Spinal Nerves: Plexus I01:22

Spinal Nerves: Plexus I

Nerve plexuses are networks of interlacing nerves that serve as communication hubs to distribute and organize nerve action across various body regions. The nerve plexuses are organized into the cervical plexus located in the neck region, brachial plexus in the shoulder area, lumbar plexus found in the lower back, sacral plexus situated in the pelvis, and coccygeal plexus located in the coccygeal region.
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...
Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Arteries of the Upper Limbs01:12

Arteries of the Upper Limbs

The subclavian artery transitions into the axillary artery as it exits the chest and enters the axillary region. This artery is critical for supplying blood to the shoulder area, including the head of the humerus, through the humeral circumflex arteries. As the vessel continues into the upper arm or brachium, it becomes the brachial artery. This artery plays a key role in vascularizing the brachial region and bifurcates at the elbow into several branches. These branches include the deep...
Bones of the Upper Limb: Ulna01:15

Bones of the Upper Limb: Ulna

The ulna and radius are parallel bones of the antebrachium or the forearm. The ulna lies medially and consists of a bony tip called the olecranon process at its proximal end. This hook-like projection articulates with the olecranon fossa of the humerus and forms the "hinged" ulnohumeral part of the elbow joint. This joint facilitates forearm extension and flexion while preventing its hyperextension. Similarly, the coronoid process, another bony projection on the proximal/anterior side of the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Optimal management of thumb basal joint arthritis: challenges and solutions.

Orthopedic research and reviews·2019
Same author

Determination of the Central Axis of the Scaphoid.

Journal of wrist surgery·2015
Same author

Thumb carpometacarpal arthroplasty with ligament reconstruction and interposition costochondral arthroplasty.

Journal of wrist surgery·2014
Same author

Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model.

The Journal of hand surgery·2007
Same author

Remodeling of articular defects in an animal model.

Clinical orthopaedics and related research·2004
Same author

Treatment of isolated perilunate and lunate dislocations with combined dorsal and volar approach and intraosseous cerclage wire.

The Journal of hand surgery·2004

Related Experiment Video

Updated: May 29, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
11:21

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation

Published on: March 13, 2026

Radial side (1D) tears.

Thomas Trumble1

  • 1Bellevue Bone and Joint Physicians, Affiliate Physician Overlake Hospital Medical Center, Department of Orthopaedic Surgery, 1632 116th Avenue NE #C, Bellevue, WA 98040, USA. t.trumble@comcast.net

Hand Clinics
|August 30, 2011
PubMed
Summary

Radial tears of the triangular fibrocartilage complex (TFCC) disrupt wrist function. Arthroscopic TFCC repair using sutures through bone tunnels effectively restores strength and motion, enabling return to activities.

Area of Science:

  • Orthopedic surgery
  • Wrist biomechanics
  • Sports medicine

Background:

  • The triangular fibrocartilage complex (TFCC) is crucial for wrist rotation and stability.
  • Radial (Type 1D) TFCC tears are uncommon but significantly impair the articulation between the carpus and distal ulna.

Purpose of the Study:

  • To describe the arthroscopic repair of radial TFCC tears.
  • To evaluate the functional recovery following TFCC repair.

Main Methods:

  • Arthroscopic TFCC repair utilizing sutures passed through bone tunnels in the radius.
  • Assessment of patient outcomes including strength and range of motion.

Main Results:

  • Successful reattachment of the TFCC to the radius.

More Related Videos

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
08:27

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel

Published on: May 23, 2025

Related Experiment Videos

Last Updated: May 29, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
11:21

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation

Published on: March 13, 2026

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
08:27

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel

Published on: May 23, 2025

  • Significant recovery of wrist strength and range of motion observed post-procedure.
  • Conclusions:

    • Arthroscopic TFCC repair is an effective treatment for radial TFCC tears.
    • The procedure facilitates patient return to work and sports activities with restored function.