Fast liquid chromatography-diode array detection assisted by chemometrics for quantification of seven ultraviolet
Maryam Vosough1, Nahal Rahimdoost Mojdehi
1Chemistry and Chemical Engineering Research Center of Iran, P.O. Box 14335-186 Tehran, Iran. vosough@ccerci.ac.ir
Abstract:
A fast chromatographic method is presented for simultaneous quantification of seven organic ultraviolet (UV) filters (benzophenone-3,4-methylbenzilidene camphor, octocrylene, 1-(4-tert-butylphenyl)-3-(4-methyoxyphenyl)1,3-propanedione), ethylhexyl methoxy cinnamate, ethylhexyl salicylate and homosalate) in effluent wastewater samples. The UV filters were pre-concentrated by Bond Elut-ENV cartridges and separated on an ODS column (15 cm × 0.46 cm, 5 μm) in less than 2.5 min using a non-aqueous mobile phase of methanol-acetonitrile (50:50, v/v) with flow-rate of 1.5 mL min(-1). Appropriate baseline correction through asymmetric least squares was applied to reduce the matrix of background signals in three way data. Then, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS) was implemented on the unfolded three-way data obtained from liquid chromatography with diode array detection (LC-DAD) through standard addition calibration method for handling co-eluted peaks, systematic and proportional errors. Recoveries ranging from 76% to 130% and %RSD values less than 11.2 for all UV filter shows the accuracy and precision of the proposed method in wastewater samples. In addition, statistical t-test as well as computed elliptical joint confidence region (EJCR) confirms the accuracy of the proposed method and indicates the absence of both constant and proportional errors in the predicted concentrations. This study demonstrates that coupling of the fast HPLC-DAD method with powerful algorithm of MCR-ALS can be considered as an efficient method for quantification of UV filters in highly contaminated samples of wastewaters where both time and cost per each analysis can be reduced significantly.
More Related Videos
08:13A Filter-based Surface Enhanced Raman Spectroscopic Assay for Rapid Detection of Chemical Contaminants
Published on: February 19, 2016
07:11Automated HPLC Separation Using LC-Mate: An Integrated Repetitive Autosampler and Fraction Collector for Microscale Purification
Published on: February 27, 2026
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
UV–Vis Spectrometers
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...