Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 29, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
06:26

Novel and Innovative Hybrid Technique for Type A Aortic Dissection

Published on: March 28, 2025

Anchor-wire technique for multiple plastic biliary stents to prevent stent dislocation.

Tsuyoshi Hamada1, Yousuke Nakai, Saburo Matsubara

  • 1Department of Gastroenterology, Kanto Central Hospital, 6-25-1 Kamiyouga, Setagaya-ku, Tokyo 158-8531, Japan.

World Journal of Gastroenterology
|August 31, 2011
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pulmonary embolism after treatment for massive hemoptysis: a therapeutic dilemma.

Respiratory medicine case reports·2026
Same author

Half-dose contrast media protocol using 70 kVp abdominal dynamic CT with super-resolution deep learning reconstruction: Evaluation of image quality and contrast performance.

European journal of radiology·2026
Same author

Pre-extraction Embolization of Jaw Arteriovenous Malformations to Reduce Bleeding during Tooth Extraction.

Journal of vascular and interventional radiology : JVIR·2026
Same author

Renal sinus leiomyoma mimicking papillary renal cell carcinoma: A case report.

Radiology case reports·2026
Same author

Second-Generation Hydrogel Coils for Transcatheter Arterial Embolization of Acute Arterial Bleeding in the Body Trunk.

Vascular and endovascular surgery·2025
Same author

Bleb morphology after trabeculectomy: A comparison of the Indiana Bleb Appearance Grading Scale and three-dimensional anterior segment optical coherence tomography.

Acta ophthalmologica·2025

A new anchor-wire technique prevents proximal dislocation of the first plastic biliary stent (PBS) during endoscopic placement of multiple PBSs. This method secures the initial stent, ensuring successful multi-stent procedures for obstructive jaundice.

Area of Science:

  • Gastroenterology
  • Endoscopic Procedures
  • Biliary Interventions

Background:

  • Obstructive jaundice due to cholangiocarcinoma often requires multiple plastic biliary stent (PBS) placements.
  • Proximal dislocation of the first PBS is a known complication during the insertion of subsequent stents.

Observation:

  • During endoscopic retrograde cholangiopancreatography (ERCP), proximal dislocation of the first PBS occurred in a patient needing multiple stent placements.
  • The challenge lies in maintaining the position of the initial stent while introducing additional ones.

Findings:

  • A novel
  • anchor-wire technique
  • was developed to prevent PBS proximal dislocation.
  • This technique involves using a guidewire inserted through the side hole of the first PBS, acting as an anchor during subsequent stent deployment.
Keywords:
Anchor-wire techniqueEndoscopic retrograde cholangiographyPlastic biliary stentPreventionProximal dislocation

More Related Videos

Monitoring the Wall Mechanics During Stent Deployment in a Vessel
08:28

Monitoring the Wall Mechanics During Stent Deployment in a Vessel

Published on: May 8, 2012

Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention
11:01

Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention

Published on: September 18, 2015

Related Experiment Videos

Last Updated: May 29, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
06:26

Novel and Innovative Hybrid Technique for Type A Aortic Dissection

Published on: March 28, 2025

Monitoring the Wall Mechanics During Stent Deployment in a Vessel
08:28

Monitoring the Wall Mechanics During Stent Deployment in a Vessel

Published on: May 8, 2012

Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention
11:01

Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention

Published on: September 18, 2015

  • Successful prevention of dislocation was achieved regardless of the anchor-wire's final position (duodenal bulb or third portion).
  • Implications:

    • The anchor-wire technique offers a simple and effective solution to a common problem in multiple PBS placement.
    • It enhances the success rate of endoscopic management for patients with complex biliary obstructions.
    • This method may improve patient outcomes by ensuring stable biliary drainage.