Related Experiment Video
Updated: May 29, 2026

Gold Nanoparticle Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection
Published on: May 13, 2019
Determination of morphine at gold nanoparticles/Nafion® carbon paste modified sensor electrode
Nada F Atta1, Ahmed Galal, Shereen M Azab
1Department of Chemistry, Faculty of Science, Cairo University, Giza, Egypt. nada_fah1@yahoo.com
Abstract:
A novel and effective electrochemical sensor for the determination of morphine (MO) in 0.04 mol L(-1) universal buffer solution (pH 7.4) is introduced using gold nanoparticles electrodeposited on a Nafion modified carbon paste electrode. The effect of various experimental parameters including pH, scan rate and accumulation time on the voltammetric response of MO was investigated. At the optimum conditions, the concentration of MO was determined using differential pulse voltammetry (DPV) in a linear range of 2.0 × 10(-7) to 2.6 × 10(-4) mol L(-1) with a correlation coefficient of 0.999, and a detection limit of 13.3 × 10(-10) mol L(-1), respectively. The effect of common interferences on the current response of morphine namely ascorbic acid (AA) and uric acid (UA) is studied. The modified electrode can be used for the determination of MO spiked into urine samples, and excellent recovery results were obtained.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019