Determining the limits and confounders for the 2-pentyl furan breath test by gas chromatography/mass spectrometry
Shrawan Bhandari1, Stephen Chambers, John Pearson
1University of Otago, Department of Pathology, PO Box 4345, Christchurch 8140, New Zealand.
Abstract:
Aspergillus fumigatus produces 2-pentyl furan (2-PF), a volatile compound not produced by many other pathogens or normal human metabolism. 2-Pentyl furan has been detected in the breath of patients with invasive aspergillosis (IA) by SPME pre-concentration coupled with CG/MS providing the possibility of an attractive diagnostic test. The limit of detection (LOD) and quantification (LOQ) for peak integration were assessed both statistically and empirically respectively. 2-Pentyl furan was detected from 10 of 45 food stuffs tested. Levels were highest from soymilk (3 of 3 brands), lower from pumpkin, peanuts, rolled oats 2, Ensure Plus, tinned asparagus, tinned beans and a vegetable exact (Marmite). No 2-PF was detectable in anti-fungal medications used to treat IA or commonly used cosmetics tested. There was no difference in 2-PF breath levels between morning and afternoon or fasting and non fasting samples taken from healthy subjects eating a diet without 2-PF rich foods. 2-Pentyl furan levels were present in breath samples immediately after a mouth rinse with soy milk (P<0.001), and in some subjects after ingesting soy milk and rinsing their mouth with water. The breath test for 2-PF can be conducted without an overnight fast or at a specified time provided the mouth has been rinsed 30 min or more from when 2-PF containing products have been ingested.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...