Related Experiment Video
Updated: May 29, 2026

Natural Product Discovery with LC-MS/MS Diagnostic Fragmentation Filtering: Application for Microcystin Analysis
Published on: May 31, 2019
Development and validation of a rapid method for microcystins in fish and comparing LC-MS/MS results with ELISA
Lucía Geis-Asteggiante1, Steven J Lehotay, Laurie L Fortis
1Agricultural Research Service, Eastern Regional Research Center, US Department of Agriculture, 600 East Mermaid Lane, Wyndmoor, PA 19038, USA.
Abstract:
Microcystins (MCs) are the most common cyanotoxins found worldwide in freshwater, brackish, and marine environments. The rapid and accurate analysis of MCs and nodularin (Nod-R) in fish tissue is important for determining occurrence, following trends, and monitoring exposure for risk assessment and other purposes. The aim of this study was to develop a streamlined and reliable sample preparation method for eight MCs (MC-RR, MC-YR, MC-LR, MC-WR, MC-LA, MC-LY, MC-LW, and MC-LF) and Nod-R in fish, and conduct a validation of the new method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for analysis and compare the results with a commercial enzyme-linked immunosorbent assay (ELISA) kit. Different sample preparation methods were compared, and a simple extraction protocol with acidified acetonitrile/water (3:1) followed by hexane partitioning cleanup was found to be most effective. Thorough validation of the final method was conducted, and 90-115% recoveries were achieved for all analytes except for MC-RR, which gave 130% average recovery (isotopically labeled internal standards were unavailable to correct for possible biases). The use of electrospray ionization in the negative mode gave few interferences and minimal matrix effects in the LC-MS/MS analysis overall. Precision was typically 10-20% RSD among multiple days in experiments, detection limits were <10 ng/g in the fish tissue (catfish, basa, and swai filets), and no false-positives or false-negatives occurred in blind analyses of many spiked samples. The ELISA was unable to distinguish between MCs but was found to correctly assess the presence or absence of MCs and Nod-R in the blind-fortified fish tissues. The capability of these approaches to measure covalently bound MCs was not assessed.
More Related Videos
07:13Early Detection of Cyanobacterial Blooms and Associated Cyanotoxins using Fast Detection Strategy
Published on: February 25, 2021
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016