Related Experiment Video
Updated: May 29, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Mobility of an elastic glove for extravehicular activity without prebreathing
Kunihiko Tanaka1, Mizuki Ikeda, Yosuke Mochizuki
1Department of Radiotechnology, Gifu University of Medical Science, Seki, Gifu, Japan. ktanaka@u-gifu-ms.ac.jp
Introduction:
The current U.S. extravehicular activity (EVA) suit is pressurized at 0.29 atm, which is much lower than the pressures of sea level and inside a space station. Higher pressure can reduce the risk of decompression sickness (DCS), but mobility would be sacrificed. We have demonstrated that a glove and sleeve made of elastic material increased mobility when compared with those made of nonelastic material, such as that found in the current suit. We hypothesized that an elastic glove of 0.65 atm that has no risk of DCS also has greater mobility compared with a non-elastic glove of 0.29 atm.
Methods:
The right hands of 10 healthy volunteers were studied in a chamber with their bare hands at normal ambient pressure, after donning a non-elastic glove with a pressure differential of 0.29 atm, and after donning an elastic glove with a pressure differential of 0.29 and 0.65 atm. Range of motion (ROM) of the index finger and surface electromyography (EMG) amplitudes during finger flexion were measured.
Results:
ROM with gloves was significantly smaller than that of bare hands, but was similar between conditions of gloves regardless of elasticity and pressure differentials. However, EMG amplitudes with the elastic glove of 0.29 and 0.65 atm were significantly smaller than those with the non-elastic glove of 0.29 atm.
Discussion:
The results suggest that mobility of the elastic glove of 0.65 atm may be better than that of the non-elastic glove of 0.29 atm, similar to that used in the current EVA suit.
Related Concept Videos
External and Internal Respiration
PPE Use in Healthcare Settings II: Doffing
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
PPE Use in Healthcare Settings I: Donning
Personal Protective Equipment
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...

