Related Experiment Video
Updated: May 29, 2026

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Ambient pressure proton transfer mass spectrometry: detection of amines and ammonia
D R Hanson1, P H McMurry, J Jiang
1Chemistry Department, Augsburg College, Minneapolis, Minnesota 55454, USA. hansondr@augsburg.edu
Abstract:
An instrument to detect gaseous amines and ammonia is described, and representative data from an urban site and a laboratory setting are presented. The instrument, an Ambient pressure Proton transfer Mass Spectrometer (AmPMS), consists of a chemical ionization and drift region at atmospheric pressure coupled to a standard quadrupole mass spectrometer. Calibrations show that AmPMS sensitivity is good for amines, and AmPMS backgrounds were suitably determined by diverting sampled air through a catalytic converter. In urban air at a site in Atlanta, amines were detected at subpptv levels for methyl and dimethyl amine which were generally at a low abundance of <1 and ∼3 pptv, respectively. Trimethyl amine (or isomers) was on average about 4 pptv in the morning and increased to 15 pptv in the afternoon, while triethyl amine (or isomers or amides) increased to 25 pptv on average in the late afternoon. The background levels for the 4 and 5 carbon amines and ammonia were high, and data are very limited for these species. Improvements in detecting amines and ammonia from a smog chamber were evident due to improvements in AmPMS background determination; notably dimethyl amine and its OH oxidation products were followed along with impurity ammonia and other species. Future work will focus on accurate calibration standards and on improving the sample gas inlet.
More Related Videos
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Mass Spectrometry of Amines
NMR Spectroscopy Of Amines
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei in a...
Mass Spectrum
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)