Performance evaluation of three computed radiography systems using methods recommended in American Association of
Wilbroad Muhogora1, Renato Padovani, Faustino Bonutti
1Tanzania Atomic Energy Commission, Arusha, Tanzania.
Abstract:
The performances of three clinical computed radiography (CR) systems, (Agfa CR 75 (with CRMD 4.0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates)) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers' characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...