Related Experiment Video
Updated: May 29, 2026

Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension
Published on: June 27, 2025
Right ventricular failure in idiopathic pulmonary arterial hypertension is associated with inefficient myocardial
Yeun Ying Wong1, Gerrina Ruiter, Mark Lubberink
1Department of Pulmonology, Institute for Cardiovascular Research, VU University Medical Center, Amsterdam, The Netherlands.
Background:
In idiopathic pulmonary arterial hypertension (IPAH), increased right ventricular (RV) power is required to maintain cardiac output. For this, RV O2 consumption (MVO2) must increase by augmentation of O2 supply and/or improvement of mechanical efficiency-ratio of power output to MVO2. In IPAH with overt RV failure, however, there is evidence that O2 supply (perfusion) reserve is reduced, leaving only increase in either O2 extraction or mechanical efficiency as compensatory mechanisms. We related RV mechanical efficiency to clinical and hemodynamic parameters of RV function in patients with IPAH and associated it with glucose metabolism.
Methods And Results:
The patients included were in New York Heart Association (NYHA) class II (n=8) and class III (n=8). They underwent right heart catheterization, MRI, and H2(15)O-, (15)O2-, C(15)O-, and 18FDG-PET. RV power and O2 supply were similar in both groups (NYHA class II versus class III: 0.54±0.14 versus 0.47±0.12 J/s and 0.109±0.022 versus 0.128±0.026 mL O2/min per gram, respectively). RV O2 extraction was near-significantly lower in NYHA class II compared with NYHA class III (63±17% versus 75±16%, respectively, P=0.10). As a result, MVO2 was significantly lower (0.066±0.012 versus 0.092±0.010 mL O2/min per gram, respectively, P=0.006). RV efficiency was reduced in NYHA class III (13.9±3.8%) compared with NYHA class II (27.8±7.6%, P=0.001). Septal bowing, measured by MRI, correlated with RV efficiency (r = -0.59, P=0.020). No relation was found between RV efficiency and glucose uptake rate. RV mechanical efficiency and ejection fraction were closely related (r=0.81, P<0.001).
Conclusions:
RV failure in IPAH was associated with reduced mechanical efficiency that was partially explained by RV mechanical dysfunction but not by a metabolic shift.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mitral Stenosis I: Introduction
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Pathophysiology of Heart Failure
