Size fractionation characterisation of removed organics in reverse osmosis concentrates by ferric chloride

A Y Bagastyo1, J Keller, D J Batstone

  • 1Advanced Water Management Centre, The University of Oueensland, St. Lucia, QLD 4072, Australia. a.bagastyo@uq.edu.au

Related Concept Videos

Extraction: Advanced Methods00:56

Extraction: Advanced Methods

Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is formed in...
Precipitation and Co-precipitation01:17

Precipitation and Co-precipitation

Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
Subcellular Fractionation01:32

Subcellular Fractionation

The homogenate obtained after cell lysis contains various membrane-bound organelles that can be further separated into pure fractions by subcellular fractionation. These isolates are used to study specific cellular components, analyze localized protein activity, and are even employed in diagnostics. Fractionation is typically achieved using centrifugation methods, the most common being density-gradient and differential centrifugation.
Differential Centrifugation
Differential centrifugation is...
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Filtration00:53

Filtration

Filtration is a physical separation process that involves passing a suspension through a porous medium to separate solids from fluids. During filtration, solids collect on the porous medium while liquids, also collectively known as the filtrate, pass through. The filtration medium is selected based on the filtration purpose, quantity, and nature of the precipitate. The general criteria for a suitable filtering medium are that it is inert, mechanically strong, nonabsorbent toward dissolved...