Related Experiment Video
Updated: May 29, 2026

Microvascular Decompression: Salient Surgical Principles and Technical Nuances
Published on: July 5, 2011
Microplate-bridge technique for watertight dural closures in the combined petrosal approach
Mari Kusumi1, Takanori Fukushima, Hamidreza Aliabadi
1Division of Neurosurgery, Duke University Medical Center, Durham, North Carolina, USA. kusumi@med.kitasato-u.ac.jp
Background:
Although the combined petrosal approach has significant advantages for medium to large petroclival lesions, it carries the risk of a few major complications. The cerebrospinal fluid leak rate with this approach has been reported to be as high as 15%.
Objective:
To describe an innovative technique of watertight dural closure with a long microplate-bridge technique for the combined petrosal approach.
Methods:
We describe our method of watertight dural closures with the microplate-bridge technique for combined petrosal approaches using cadaveric heads and clinical cases. We review our postoperative outcomes in respect to cerebrospinal fluid leaks.
Results:
The technique involves a fascial graft to the presigmoid-subtemporal defect, fixated with a long microtitanium plate over the cranial base side. The fascial graft is augmented by covering it with an abdominal fat graft and a vascularized pericranial flap. This technique was performed in 23 patients after surgical resection of petroclival meningiomas with only 1 postoperative cerebrospinal fluid leak (4.4%).
Conclusion:
We recommend this safe and simple closure technique during skull base surgery.