A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Diagnosis of deep-vein thrombosis using an objective Doppler method
A W Lensing1, M M Levi, H R Büller
1Academic Medical Center, Amsterdam, The Netherlands.
An objective Doppler-Valsalva pressure method accurately detects deep-leg-vein thrombosis in symptomatic outpatients. This reproducible and simple diagnostic tool aids in identifying venous thrombosis effectively.
Area of Science:
- Vascular Medicine
- Diagnostic Imaging
- Medical Technology
Background:
- Deep-leg-vein thrombosis (DLT) diagnosis in symptomatic outpatients often relies on clinical suspicion, necessitating accurate and efficient diagnostic methods.
- Contrast venography, while definitive, is invasive and carries risks, prompting the search for less invasive alternatives.
Purpose of the Study:
- To establish diagnostic criteria for an objective Doppler-Valsalva pressure method in phase I.
- To evaluate the diagnostic accuracy of this Doppler-Valsalva method compared to contrast venography in phase II for acute DLT.
Main Methods:
- A prospective, two-phase study involving consecutive outpatients with suspected venous thrombosis.
- Doppler ultrasound and Valsalva maneuver pressure measurements were correlated with contrast venography findings.
- Diagnostic criteria were established, and accuracy metrics (sensitivity, specificity) were calculated.
Main Results:
- The Doppler-Valsalva method demonstrated high diagnostic accuracy for proximal DLT in phase II.
- Sensitivity was 91% (95% CI, 79% to 98%) and specificity was 99% (CI, 97% to 100%).
- All cases of isolated calf-vein thrombosis were correctly identified as normal by the Doppler test.
Conclusions:
- The objective Doppler-Valsalva pressure method is a highly accurate, reproducible, and simple tool for diagnosing venous thrombosis.
- This non-invasive method offers a reliable alternative for the detection of DLT in symptomatic outpatients.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care