Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 29, 2026

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences
06:49

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences

Published on: June 16, 2014

A novel planar tracking technology for physiological image analysis.

Timothy M Osborne1, Martin Lakie

  • 1Applied Physiology Research Group, School of Sport and Exercise Sciences, University of Birmingham, Birmingham B15 2TT, UK. tmo643@bham.ac.uk

Journal of Neuroscience Methods
|September 13, 2011
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Intrinsic ankle stiffness is associated with paradoxical calf muscle movement but not postural sway or age.

Experimental physiology·2024
Same author

Idiosyncratic Characteristics of Postural Sway in Normal and Perturbed Standing.

Frontiers in human neuroscience·2021
Same author

Individual differences in intrinsic ankle stiffness and their relationship to body sway and ankle torque.

PloS one·2021
Same author

Muscle thixotropy-where are we now?

Journal of applied physiology (Bethesda, Md. : 1985)·2019
Same author

Visuo-manual tracking: does intermittent control with aperiodic sampling explain linear power and non-linear remnant without sensorimotor noise?

The Journal of physiology·2017
Same author

Physiological tremor reveals how thixotropy adapts skeletal muscle for posture and movement.

Royal Society open science·2016
Same journal

Detection of cochlear microphonic for differential diagnosis between auditory neuropathy mice and noise-induced sensorineural hearing loss mice.

Journal of neuroscience methods·2026
Same journal

Assessment metrics for pain control in rats: A methodological commentary.

Journal of neuroscience methods·2026
Same journal

Infant EEG preprocessing pipelines: A capability framework and current gaps in practice.

Journal of neuroscience methods·2026
Same journal

Methods for measuring neural activity during voluntary wheel running.

Journal of neuroscience methods·2026
Same journal

Serotype-dependent differences in AAV cellular transduction rates in the hypothalamus of Arctic ground squirrels.

Journal of neuroscience methods·2026
Same journal

Rapid generation of human sensory neurons from iPSC for modeling of peripheral neuropathies.

Journal of neuroscience methods·2026
See all related articles

Novel planar tracking technology, originally for special effects, offers an accessible alternative to point tracking for physiological studies. This method shows promise for improving image analysis, especially with low-quality imaging like ultrasonography.

Area of Science:

  • Physiology
  • Biomedical Engineering
  • Image Analysis

Background:

  • Automated image tracking is crucial for physiological studies but current methods (point tracking) are often complex and ad hoc.
  • Existing techniques struggle with low-quality or noisy image data common in some physiological measurements.

Purpose of the Study:

  • To evaluate a novel planar tracking technology for physiological measurements.
  • To assess the accuracy, repeatability, and flexibility of this new non-point-tracking method.
  • To explore its utility in challenging imaging scenarios, such as ultrasonography.

Main Methods:

  • Tested a commercially available planar tracking system, distinct from traditional point tracking methods.
  • Validated the technology through accuracy and repeatability measurements.

More Related Videos

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
06:09

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography

Published on: March 12, 2021

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
07:21

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking

Published on: February 12, 2011

Related Experiment Videos

Last Updated: May 29, 2026

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences
06:49

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences

Published on: June 16, 2014

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
06:09

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography

Published on: March 12, 2021

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
07:21

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking

Published on: February 12, 2011

  • Applied the software to conduct two dynamic physiological measurements.
  • Main Results:

    • The planar tracking technology demonstrated reliable accuracy and repeatability in validation tests.
    • Physiological measurements confirmed the software's flexibility and adaptability.
    • The technique proved effective even with simulated low-quality image data.

    Conclusions:

    • Planar tracking offers a user-friendly and effective alternative to point tracking for automated image analysis in physiological research.
    • This technology is particularly advantageous for techniques yielding low-quality images, such as ultrasonography.
    • It enhances the potential for quantitative physiological insights from previously challenging imaging modalities.