Modified Experimental Conditions for Noise-Induced Hearing Loss in Mice and Assessment of Hearing Function and Outer Hair Cell Damage
Published on: February 10, 2023
[Assessment of telephone operators' exposure to sound through headphones]
Shoko Kawanami1, Jinro Inoue, Koko Takahashi
1Department of Health Policy and Management, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health.
Abstract:
We estimated the level of noise that telephone operators were exposed to through headphones by a two-step method using an artificial ear technique and a manikin technique. In the artificial ear technique, the sound pressure level (Leq) of the total work hours was 81.5 dB, whereas the Leq of the total duration of phone calls was 89.3 dB. Therefore, we conducted a more accurate measurement by the manikin technique (ISO11904-2). By this method, we could simulate the headphone-wearing condition of the workers and convert the measurements to a diffuse-field related L(Aeq). By this manikin technique, the corrected L(Aeq) of the total work hours was 68.3 dB, whereas the corrected L(Aeq) of the total duration of call was 76.6 dB, which was below the standard of the Occupational Exposure Limits of the Japan Society of Occupational Health. We confirmed that in a workplace where the background noise is low (51.3 dBA), a good signal-noise ratio is maintained so that operators don't have to listen to loud sounds through headphones. Neither the gender nor the type of the telephone equipment of the callers affected the sound pressure levels.
More Related Videos
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Design Example
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same frequency...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: