A randomized crossover comparison between the Laryngeal Mask Airway-Unique™ and the air-Q intubating laryngeal airway
Narasimhan Jagannathan1, Lisa E Sohn, Ravinder Mankoo
1Children's Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60614, USA. simjag2000@yahoo.com
Objectives:
The purpose of this randomized crossover study was to evaluate the feasibility of the air-Q intubating laryngeal airway (ILA) in clinical practice when compared with the Laryngeal Mask Airway-Unique(™) (LMA-U), the current standard of care for primary airway maintenance.
Aim:
We hypothesized that the ILA would have better airway seal pressures and laryngeal alignment than the LMA-U in anesthetized nonparalyzed children.
Background:
The ILA is a newer supraglottic airway for children with design features that allow it to be used for primary airway maintenance and as a conduit for tracheal intubations.
Methods:
Fifty healthy children, 6-36 months of age, 10-15 kg, who were scheduled for elective surgery in which the use of a size two LMA-U and size 1.5 ILA would be appropriate for airway maintenance, were enrolled into this randomized crossover study. Primary outcome measures were airway leak pressures and fiberoptic grades of view. Secondary outcome measures included ease and time for successful insertion, incidence of gastric insufflation, ventilation parameters, and complications.
Results:
There were no statistically significant differences in regard to the ease of device insertion, time to ventilation, gastric insufflation, and ventilation parameters between the ILA and the LMA-U. All devices were successfully placed on the first attempt, and there were no instances of failure. There were statistically significant differences in the airway leak pressure between the ILA (19.0 ± 5.4 cmH(2)O) and the LMA-U (16.1 ± 4.9 cmH(2)O), P = 0.001. There were also statistically significant differences in the fiberoptic grades of view between the ILA and LMA-U, P = 0.004.
Conclusions:
The ILA had higher airway leak pressures and superior fiberoptic grades of view when compared with the LMA-U and can be a suitable alternative to the LMA-U in children weighing 10-15 kg.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...