Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a high-sensitivity assay
Richard Body1, Simon Carley, Garry McDowell
1University of Manchester, Manchester, United Kingdom. richard.body@manchester.ac.uk
Objectives:
This paper sought to evaluate whether high sensitivity troponin (hs-cTnT) can immediately exclude acute myocardial infarction (AMI) at a novel 'rule out' cut-off.
Background:
Subgroup analysis of recent evidence suggests that undetectable hs-cTnT may exclude AMI at presentation.
Methods:
In a cohort study, we prospectively enrolled patients with chest pain, evaluating them with standard troponin T and testing for hs-cTnT (Roche Diagnostics, Basel, Switzerland) at presentation. The primary outcome was a diagnosis of AMI. We also followed up patients for adverse events within 6 months. After subsequent clinical implementation of hs-cTnT, we again evaluated whether initially undetectable hs-cTnT ruled out a subsequent rise.
Results:
Of 703 patients in the cohort study, 130 (18.5%) had AMI, none of whom initially had undetectable hs-cTnT (sensitivity: 100.0%, 95% confidence interval [CI]: 95.1% to 100.0%, negative predictive value: 100.0%, 95% CI: 98.1% to 100.0%). This strategy would rule out AMI in 27.7% of patients, 2 (1.0%) of whom died or had AMI within 6 months (1 periprocedural AMI, 1 noncardiac death). We evaluated this approach in an additional 915 patients in clinical practice. Only 1 patient (0.6%) with initially undetectable hs-cTnT had subsequent elevation (to 17 ng/l), giving a sensitivity of 99.8% (95% CI: 99.1% to 100.0%) and a negative predictive value of 99.4% (95% CI: 96.6% to 100.0%).
Conclusions:
Undetectable hs-cTnT at presentation has very high negative predictive value, which may be considered to rule out AMI, identifying patients at low risk of adverse events. Pending further validation, this strategy may reduce the need for serial testing and empirical treatment, enabling earlier reassurance for patients and fewer unnecessary evaluations and hospital admissions.
More Related Videos
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Myocarditis II: Clinical Features and Diagnostic Tests
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes