Related Experiment Video
Updated: May 29, 2026

Erosion Identification in Metacarpophalangeal Joints in Rheumatoid Arthritis using High-Resolution Peripheral Quantitative Computed Tomography
Published on: October 6, 2023
Identification of intraarticular and periarticular uric acid crystals with dual-energy CT: initial evaluation
Katrina N Glazebrook1, Luis S Guimarães, Naveen S Murthy
1Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA.
Purpose:
To estimate the accuracy, sensitivity, specificity, and interobserver agreement of dual-energy computed tomography (CT) in detection of uric acid crystals in joints or periarticular structures in patients with arthralgia and patients suspected of having gout, with joint aspiration results as reference standard.
Materials And Methods:
With institutional review board approval, patient consent, and HIPAA compliance, 94 patients (age range, 29-89 years) underwent dual-source, dual-energy (80 and 140 kVp) CT of a painful joint. A material decomposition algorithm was used to identify uric acid. Two blinded musculoskeletal radiologists evaluated the dual-energy CT images and classified the examination findings as positive or negative for the presence of uric acid crystals. Reference standard was the result of joint aspiration.
Results:
Forty-three of 94 patients (46%) underwent attempted joint aspiration within 1 month of dual-energy CT. Aspiration was successful in 31 of 43 patients (72%). In 12 of 31 patients (39%), uric acid crystals were identified at joint aspiration; in 19 patients, they were not. Readers 1 and 2 had no false-negative findings for uric acid at dual-energy CT. Sensitivity was 100% (12 of 12; 95% confidence interval (CI): 74%, 100%) for both readers. Specificity was 89% (17 of 19; 95% CI: 67%, 99% ) for reader 1 and 79% (15 of 19; 95% CI: 54%, 94%) for reader 2, with near-perfect agreement between the readers (κ = 0.87; range, 0.70-1.00) in the 31 patients who underwent aspiration.
Conclusion:
Initial retrospective assessment suggests that dual-energy CT is a sensitive, noninvasive, and reproducible method for identifying uric acid deposits in joints and periarticular soft tissues in patients suspected of having gout.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies III: Computed Tomography
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Urinary Tract Calculi III: Medical Management
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
