Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Developing qualitative extraction profiles of coffee aromas utilizing polymeric ionic liquid sorbent coatings in
Jessica López-Darias1, Jared L Anderson, Verónica Pino
1Department of Chemistry, The University of Toledo, Toledo, OH 43606, USA.
Abstract:
Two solid-phase microextraction (SPME) sorbent coatings based on polymeric ionic liquids (PILs) have been utilized for the analysis of complex coffee aroma samples. The PIL-based SPME coatings examined, namely, poly(1-(4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide) [poly(VBHDIm(+) NTf(2)(-))], with ~14-μm thickness, and poly(1-vinyl-3-hexylimidazolium chloride) [poly(ViHIm(+)Cl(-))], with ~8-μm thickness, were employed for the headspace determination of up to 49 analytes from four different coffee beans: two French roast coffees of different brands, Sumatra coffee, and decaffeinated Sumatra coffee. The analysis was conducted using gas chromatography coupled to mass spectrometry. For comparative purposes, the commercial polyacrylate (PA, 85-μm film thickness) SPME coating was utilized under the same extraction conditions. The three SPME coatings tested behaved quite differently as a function of the families of compounds extracted. Thus, the poly(VBHDIm(+) NTf(2)(-) ) coating was extremely selective for aldehydes while also exhibiting good extraction efficiencies for acids. The poly-(ViHIm(+) Cl(-)) coating exhibited superior performance for aromatic alcohols, and the PA coating worked better for heterocyclic aromatics. Both PIL-based SPME sorbent coatings demonstrated exceptional selectivity and extraction efficiency when dealing with complex coffee aromas in spite of their small film thicknesses.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...