Related Experiment Video
Updated: May 29, 2026

A Uniaxial Compression Experiment with CO2-Bearing Coal Using a Visualized and Constant-Volume Gas-Solid Coupling Test System
Published on: June 12, 2019
Noise variability in underground room and pillar coal mines
Marek L Szary1, Yoginder P Chugh, Joseph Hirschi
1College of Engineering, Southern Illinois University, Carbondale, IL 62901, USA. szary@engr.siu.edu
Abstract:
Noise in an underground coal mine has dominant components generated mainly from 3 sources: (a) continuous mining machines, (b) roof bolters, and (c) cars/vehicles used to transport personnel and/or coal. Each of these 3 noise sources also has a number of well-defined sub-sources with their own noise characteristics. Sound level meters were used to collect noise data in the form of instantaneous readings and also to check calibration of other sound measuring instruments. The most useful information was obtained from a spectrum analysis of continuous digital recordings of noise over time. This paper discusses the variability or dynamics of generated noise in both frequency and time domains in relation to several independent variables related to coal extraction and transportation processes.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Unsoundness of Aggregate due to Volume Change
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Random Error
