Related Experiment Video
Updated: May 29, 2026

Virtual Hand with Ambiguous Movement between the Self and Other Origin: Sense of Ownership and 'Other-Produced' Agency
Published on: October 28, 2020
Dynamic changes in the perceived posture of the hand during ischaemic anaesthesia of the arm
N Inui1, L D Walsh, J L Taylor
1Neuroscience Research Australia, Sydney, 2031, Australia.
Abstract:
Contorted 'phantom' limbs often form when sensory inputs are removed, but the neural mechanisms underlying their formation are poorly understood. We tracked the evolution of an experimental phantom hand during ischaemic anaesthesia of the arm. In the first study subjects showed the perceived posture of their hand and fingers using a model hand. Surprisingly, if the wrist and fingers were held straight before and during anaesthesia, the final phantom hand was bent at the wrist and fingers, but if the wrist and fingers were flexed before and during anaesthesia, the final phantom was extended at wrist and fingers. Hence, no 'default' posture existed for the phantom hand. The final perceived posture may depend on the initial and evolving sensory input during the block rather than the final sensory input (which should not differ for the two postures). In the second study subjects selected templates to indicate the perceived size of their hand. Perceived hand size increased by 34 ± 4% (mean ± 95% CI) during the block. Sensory changes were monitored. In all subjects, impairment of large-fibre cutaneous sensation began distally with von Frey thresholds increasing before cold detection thresholds (Aδ fibres) increased. Some C fibres subserving heat pain still conducted at the end of cuff inflation. These data suggest that changes in both perceived hand size and perceived position of the finger joints develop early when large-fibre cutaneous sensation is beginning to degrade. Hence it is unlikely that block of small-fibre afferents is critical for phantom formation in an ischaemic block.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Alterations in Muscle Tone lll
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Alterations in Muscle Tone ll
Pre-Procedural Guidelines for Assessing Blood Pressure