Related Experiment Video
Updated: May 29, 2026

Deployment and Retrieval of Mineral Samplers
Published on: January 20, 2026
In situ stabilization of trace metals in a copper-contaminated soil using P-spiked Linz-Donawitz slag
Osama Negim1, Michel Mench, Clémence Bes
1Université de Bordeaux, EA 4592 Géoressources & Environnement, Institut EGID, 1 Allée F. Daguin, 33607 Pessac, France.
Purpose:
A former wood exploitation revealing high Cu and As concentration of the soils served as a case study for assisted phytoextraction.
Method:
P-spiked Linz-Donawitz (LD) slag was used as a soil additive to improve physico-chemical soil properties and in situ stabilize Cu and other trace metals in a sandy Cu-contaminated soil (630 mg kg⁻¹ soil). The LD slag was incorporated into the contaminated soil to consist four treatments: 0% (T1), 1% (T2), 2% (T3), and 4% (T4). A similar uncontaminated soil was used as a control (CTRL). After a 1-month reaction period, potted soils were used for a 2-week growth experiment with dwarf beans.
Results:
Soil pH increased with the incorporation rate of LD slag. Similarly the soil electrical conductivity (EC, in millisiemens per centimetre) is ameliorated. Bean plants grown on the untreated soil (T1) showed a high phytotoxicity. All incorporation rates of LD slag increased the root and shoot dry weight yields compared to the T1. The foliar Ca concentration of beans was enhanced for all LD slag-amended soil, while the foliar Mg, K, and P concentrations were not increased. Foliar Cu, Zn, and Cr concentrations of beans decreased with the LD slag incorporation rate.
Conclusions:
P-spiked LD slag incorporation into polluted soil allow the bean growth and foliar Ca concentration, but also to reduce foliar Cu concentration below its upper critical value avoiding an excessive soil EC and Zn deficiency. This dual effect can be of interest for soil remediation at larger scale.
More Related Videos
Related Concept Videos
Microbial Leaching
Extraction: Advanced Methods
Acid Mine Drainage
Microbial Bioremediation of Uranium
Precipitation and Co-precipitation
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...