Related Experiment Video
Updated: May 29, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Correlation of measurements from diffusion weighted MR imaging and FDG PET/CT in GIST patients: ADC versus SUV
Chun Sing Wong1, Nanjie Gong, Yiu-Ching Chu
1Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong. drcswong@gmail.com
Purpose:
We investigated the correlation relationship between ADCs measured by MRI and SUVs measured by PET/CT of lesions on GIST (gastrointestinal stromal tumor) patients to verify if MR is able to replace or serve as an alternative to PET/CT in GIST staging and treatment monitoring.
Materials And Methods:
Between September 2010 and January 2011, five patients with histologically proven metastatic GIST in Queen Mary Hospital, Hong Kong were enrolled into our study. All patients underwent both MRI and PET/CT scans at prognosis. Pearson's correlations of twenty-nine lesions were conducted between 5 pairs of ADCs and SUVs values.
Results:
Lesions in the liver, peritoneum or bowel loops were found by PET/CT and no extra-abdominal lesion was identified. All twenty-nine lesions are identifiable by MRI with sensitivity of 100%. Significant inverse correlation were found between ADC(mean) and SUV(mean) (P=0.006), ADC(mean) and SUV(max) (P=0.010), ADC(min) and SUV(max) (P=0.014), ADC(min) and SUV(mean) (P=0.026), rADC(min) and rSUV(max) (P=0.047).
Conclusion:
DWI is comparable to PET/CT in visually detecting the GIST lesions' location. Significant inverse correlations were found between ADCs from DWIBS and SUVs from PET/CT on data of GIST patients. This finding demonstrates that DWI is potentially capable of offering similar information for diagnosis and treatment response evaluating in GIST's patients as PET/CT does. Furthermore, ADC(min), which is determined by single pixel, is not as reliable as ADC(mean), which is weighted average value of the whole lesion volume.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...