Related Experiment Video
Updated: May 29, 2026

Separation of Aldehydes and Reactive Ketones from Mixtures Using a Bisulfite Extraction Protocol
Published on: April 2, 2018
Intermittent trickling bed filter for the removal of methyl ethyl ketone and methyl isobutyl ketone
Danvir Mark C Farnazo1, Grace M Nisola, Mideok Han
1Energy and Environment Fusion Technology Center (E2FTC), Department of Environmental and Biotechnology, Myongji University, Namdong, Cheoin-gu, Gyeonggi-do, Republic of Korea.
Abstract:
Biodegradations of methyl ethyl ketone and methyl isobutyl ketone were performed in intermittent biotrickling filter beds (ITBF) operated at two different trickling periods: 12 h/day (ITBF-12) and 30 min/day (ITBF-0.5). Ralstonia sp. MG1 was able to degrade both ketones as evidenced by growth kinetic experiments. Results show that trickling period is an important parameter to achieve high removal performance and to maintain the robustness of Ralstonia sp. MG1. Overall, ITBF-12 outperformed ITBF-0.5 regardless of the target compound. ITBF-12 had high performance recovery at various inlet gas concentrations. The higher carbon dioxide production rates in ITBF-12 suggest higher microbial activity than in ITBF-0.5. Additionally, lower concentrations of absorbed volatile organic compound (VOC) in trickling solutions of ITBF-12 systems also indicate VOC removal through biodegradation. Pressure drop levels in ITBF-12 were relatively higher than in ITBF-0.5 systems, which can be attributed to the decrease in packed bed porosity as Ralstonia sp. MG1 grew well in ITBF-12. Nonetheless, the obtained pressure drop levels did not have any adverse effect on the performance of ITBF-12. Biokinetic constants were also obtained which indicated that ITBF-12 performed better than ITBF-0.5 and other conventional biotrickling filter systems.
More Related Videos
06:45Continuous Liquid-Liquid Extraction of Medium-Chain Fatty Acids from Fermentation Broth Using Hollow-Fiber Membranes
Published on: August 9, 2024
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
Related Concept Videos
Filtration
Dialysis
Biological Treatment of Effluent and Waste Water
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration