Study of Short Peptide Adsorption on Solution Dispersed Inorganic Nanoparticles Using Depletion Method
Published on: April 11, 2020
Quantitative analysis of adsorbed proteins by X-ray photoelectron spectroscopy
Santanu Ray1, Alexander G Shard
1National Physical Laboratory, Teddington, Middlesex, UK. santanu.ray@npl.co.uk
Abstract:
Protein adsorption at solid surfaces is central to many phenomena of medical and technological interest. The determination of the amount of protein attached to the surface is a critical measurement performed by using a wide range of methods. X-ray photoelectron spectroscopy (XPS) is able to provide a straightforward quantitative analysis of the amount of protein adsorbed as an overlayer on a material surface. While XPS is commonly employed to assess qualitatively the amount of adsorbed protein, this is usually expressed in terms of the elemental fraction (or at. %) of nitrogen calculated using an assumption of depth homogeneity despite the fact that this does not linearly scale with the amount of protein. In this paper, we have shown that thicknesses derived from XPS data linearly correlated with spectroscopic ellipsometry data on the same samples with a scatter of 10%. A straightforward equation to convert the concentration of nitrogen from XPS into an equivalent thickness of a protein film is presented. We highlight some discrepancies in the absolute thicknesses determined by XPS and ellipsometry on dried films and quartz crystal microbalance on wet films, which appear likely to result from the inclusion of a contribution from water in the latter two techniques.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...