Related Experiment Video
Updated: May 28, 2026

Learning Modern Laryngeal Surgery in a Dissection Laboratory
Published on: March 18, 2020
Arytenoid adduction combined with medialization laryngoplasty under general anesthesia using a laryngeal mask airway
Takeharu Kanazawa1, Yusuke Watanabe, Mariko Hara
1Department of Otolaryngology/Head and Neck Surgery, Jichi Medical University Saitama Medical Center, Saitama City, Saitama, Japan. kanatake@omiya.jichi.ac.jp
Purpose:
Laryngeal framework surgery is usually performed under local anesthesia but cannot be tolerated by some patients. To develop a new procedure for these patients, we evaluated voice outcomes after arytenoid adduction combined with medialization laryngoplasty under general anesthesia using a laryngeal mask airway (LMA) for unilateral vocal cord paralysis.
Materials And Methods:
Eleven consecutive patients with severe unilateral vocal cord paralysis, with a maximum phonation time of less than 5 seconds, underwent arytenoid adduction combined with medialization laryngoplasty under general anesthesia using an LMA. Each paralyzed vocal cord was observed by intraoperative videolaryngoscopy. The vocal cord was moved to the position where the best vocal outcome could be expected, according to 3 parameters obtained from glottal images.
Results:
All patients achieved a maximum phonation time of more than 11 seconds. The mean airflow rate, which ranged from 550 to 1000 mL/s before surgery, improved to less than 390 mL/s. Perceptual evaluation using the grade, roughness, breathiness, asthenia and strain scale also improved significantly.
Conclusions:
These results were equivalent to those of previous reports of surgeries performed under local anesthesia. Intraoperative endoscopic vocal cord observation through the LMA may have contributed to the positive results.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Larynx
Anatomy of the Larynx
The larynx consists of various components, including cartilage, muscles, and vocal cords. Its structure includes three large unpaired cartilages—the thyroid, cricoid, and epiglottis—and three smaller paired cartilages—the arytenoids, corniculates, and...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...