Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Quantifying temperature and flow rate effects on the performance of a fixed-bed chromatographic reactor
Tien D Vu1, A Seidel-Morgenstern
1Hanoi University of Science and Technology, School of Chemical Engineering, 1 Dai Co Viet, Hanoi, Viet Nam.
Abstract:
Chromatographic reactors are based on coupling chemical reactions with chromatographic separation in fixed-beds. Temperature and flow rate are important parameters for the performance of such reactors. Temperature affects mainly adsorption, chemical equilibria, mass transfer and reaction kinetics, whereas flow rate influences residence time and dispersion. In order to evaluate the mentioned effects, the hydrolysis reactions of methyl formate (MF) and methyl acetate (MA) were chosen as case studies. These reactions were performed experimentally in a lab-scale fixed-bed chromatographic reactor packed with a strong acidic ion exchange resin. The chosen reactions can be considered to represent a relative fast (MF) and a relative slow (MA) reaction. The processes which take place inside the reactor were described and simulated using an isothermal equilibrium dispersive model. The essential model parameters were determined experimentally at different temperatures and flow rates. The performance of the chromatographic reactor was evaluated at several discrete constant temperature levels by quantifying product purity, productivity and yield. The work provides insight regarding the influence of temperature and flow rate on values of the model parameters and the performance criteria.
More Related Videos
10:00Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture
Published on: July 20, 2022
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Principles Of Column Chromatography
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...