Quantitative waveform measures of the electrocardiogram as continuous physiologic feedback during resuscitation with
David D Salcido1, Young-Min Kim, Lawrence D Sherman
1University of Pittsburgh, Pittsburgh, PA 15260, USA. salcidodd@upmc.edu
Background:
There are few if any real-time physiologic measures that currently provide feedback during resuscitation from cardiac arrest. Such measures could be used to guide therapy not simply based on process guidelines but on the physiologic response of the patient from moment to moment. To this end, we applied an existing technology - quantitative waveform measures (QWMs) of the ventricular fibrillation (VF) electrocardiogram (ECG) - as a continuous measure of myocardial response to reperfusion with cardiopulmonary bypass (CPB) after prolonged cardiac arrest.
Methods:
Sixteen domestic, mixed-breed swine were sedated, anesthetized and paralyzed. Mechanical ventilation with room air was provided. Large diameter bypass catheters were placed in the right external jugular vein and right femoral artery for cardiopulmonary bypass (CPB). VF was induced with a 3-s 100mA transthoracic shock and left untreated for 15, 20, 25, or 30min, followed by 10min of centrifugal pump CPB (Bard CPS). Continuous Lead II ECG was recorded with an electronic data acquisition system (Power Lab, ADInstruments). Four QWMs representing 4 signal characteristics of the VF ECG were calculated in 5-s windows throughout the course of untreated VF and resuscitation with CPB.
Results:
Four animals were assigned to each VF duration group. QWM recovery was inversely correlated with untreated VF duration, and was drastically reduced above 20min of untreated VF. Return of spontaneous circulation (ROSC) was highly unlikely after 20min of untreated VF.
Conclusion:
QWMs of the VF ECG provided a real-time metric of myocardial electrophysiologic response to reperfusion with CPB. Resuscitation from greater than 20min of untreated cardiac arrest was unlikely. QWMs may be useful for titrating CPB duration before defibrillation and assessing CPR quality independently of process guidelines.
More Related Videos
09:05Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Published on: January 30, 2015
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...