Related Experiment Video
Updated: May 28, 2026

Detection of Targetable Alterations in Non-small Cell Lung Cancer using Next-generation Sequencing
Published on: October 10, 2025
Role of training activities for the reduction of pre-analytical errors in laboratory samples from primary care
Adolfo Romero1, Andrés Cobos, Juan Gómez
1Unidad de Gestión Clínica de Hematología y Laboratorio, Hospital Universitario Virgen de la Victoria, Málaga, Spain. preanalitica@gmail.com
Background:
The presence of pre-analytical errors (PE) is a usual contingency in laboratories. The incidence may increase where it is difficult to control that period, as it is the case with samples sent from primary care (PC) to clinical reference laboratory. Detection of a large number of PE in PC samples in our Institution led to the development and implementation of preventive strategies. The first of these has been the realization of a cycle of educational sessions for PC nurses, followed by the evaluation of their impact on PE number.
Methods:
The incidence of PE was assessed in two periods, before (October-November 2007) and after (October-November, 2009) the implementation of educational sessions. Eleven PC centers in the urban area and 17 in the rural area participated. In the urban area, samples were withdrawn by any PC nurse; in the rural area, samples were obtained by the patient's reference nurse. The types of analyzed PE included missed sample (MS), hemolyzed sample (HS), coagulated sample (CS), incorrect sample (ISV) and others (OPE), such as lipemic or icteric serum or plasma.
Results:
In the former period, we received 52,669 blood samples and 18,852 urine samples, detecting 3885 (7.5%) and 1567 (8.3%) PEs, respectively. After the educational intervention, there were 52,659 and 19,048 samples with 5057 (9.6%) and 1.256 (6.5%) PEs, respectively (p<0.001). According to the type of PE, the incidents compared before and after compared incidences were: MS, 4.8% vs. 3.8%, p<0.001; HS, 1.97% vs. 3.9%, p<0.001; CS, 0.54% vs. 0.25%, p<0.001; ISV, 0.15% vs. 0.19% p=0.08; and OPE, 0.3% vs. 0.42%, p<0.001.
Conclusions:
Surprisingly the PE incidence increased after the educational intervention, although it should be noted that it was primarily due to the increase of HS, as the other EP incidence decreased (MS and CS) or remained unchanged (ISV). This seems to indicate the need for a comprehensive approach to reduce the incidence of errors in the pre-analytical period, as one stage interventions do not seem to be effective enough.
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Errors occurring during blood pressure monitoring
Several factors...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Data Validation
Key parameters for method validation include: