'Safe' methaemoglobin concentrations are a mortality risk factor in patients receiving inhaled nitric oxide
L Rolley1, H Bandeshe, R J Boots
1Department of Intensive Care Medicine, Royal Brisbane and Women's Hospital and Burns Trauma and Critical Care Research Centre, University of Queensland, Brisbane, Queensland, Australia.
Abstract:
Inhaled nitric oxide (iNO) can reduce pulmonary arterial hypertension and improve oxygenation in some patients with severe respiratory or heart failure. Despite this, iNO has not been found to improve survival. This study aimed to perform a local practice audit to assess the mortality predictors of critically ill patients who had received iNO as therapy for pulmonary hypertension and respiratory or heart failure. A retrospective audit in a single tertiary centre intensive care unit of patients receiving iNO was conducted between 2004 and 2009. The indications for iNO use, comorbidities, severity of illness, organ function, oxygenation, Sequential Organ Failure Assessment scores, patterns of iNO use, adverse events and outcomes were reviewed. In 215 patients receiving iNO, improvement in oxygenation after one hour from iNO commencement did not predict either intensive care unit (P = 0.36) or hospital (P = 0.72) mortality. The independent risk factors for intensive care unit mortality were worsening Sequential Organ Failure Assessment scores within 24 hours of commencing iNO (adjusted odds ratio 1.07, 95% confidence interval 1.05 to 1.18), the Charlson Comorbidity Score (adjusted odds ratio 1.49, 95% confidence interval 1.16 to 1.91) and the peak methaemoglobin concentration in arterial blood while receiving iNO (adjusted odds ratio 2.67, 95% confidence interval 1.42 to 4.96). Inhaled nitric oxide as salvage therapy for severe respiratory failure in critically ill patients is not routinely justified. Increased methaemoglobin concentration during iNO therapy, even when predominantly less than 3%, is associated with increased mortality.
More Related Videos
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Inhalational Anesthetics: Overview
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
2° Amines to N-Nitrosamines: Reaction with NaNO2