Related Experiment Video
Updated: May 28, 2026

Iridium(III) Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015
A versatile and highly sensitive probe for Hg(II), Pb(II) and Cd(II) detection individually and totally in water
Yu Zhou1, Xiang-Li Tian, Yan-Song Li
1Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis, Jilin University, Changchun 130062, PR China. zhouyu69@sina.com
Abstract:
The detection of heavy metal ions using enzyme-linked immunosorbent assays (ELISA) has been reported by several research groups. However, highly sensitive and selective detection of total heavy metal ions using ELISA is a major technical limitation. Here we describe the development of a versatile and highly sensitive probe combining goat anti-mice IgG, colloidal gold nanoparticles (AuNPs) and horseradish peroxidase (HRP). We demonstrate the utility of this probe using three kinds of heavy metal complete antigens and three monoclonal antibodies (McAbs) in one ELISA system to establish a high-throughput screening protocol. The procedure was successfully applied to analysis of Hg(II), Pb(II) and Cd(II) individually and totally from different water samples. The sensitivities for the detection of Hg(II), Pb(II) and Cd(II) individually and totally are 27.4, 3.9, 15.8 and 18.2 nM, respectively. And all limit of detection (LODs) are lower than 1.2 nM. The recovery results obtained from the developed technique showed a good correlation (R(2)=0.983) with those from ICP-MS. The major advantage of the probe is the versatility and high sensibility. The probe could be potentially used, upon demand, as a sensitive and versatile detector for a broad range of applications.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
UV–Vis Spectrometers

