Related Experiment Video
Updated: May 28, 2026

07:11
Treatment of Facial Deformities using 3D Planning and Printing of Patient-Specific Implants
Published on: May 23, 2020
Orbital emphysema following removal of bilateral midfacial implants
Daniel Brettell1, Kenneth G-J Ooi, Allan Bank
1Prince of Wales Hospital, Randwick, Australia. dan.brettell@gmail.com
Orbit (Amsterdam, Netherlands)
|October 8, 2011
Abstract:
A 36-year-old man with Crouzon syndrome was referred post-operatively with unilateral painful limitation of eye movements and proptosis following removal of bilateral malar and orbital rim implants. Further investigation revealed right inferior orbital emphysema, caused by the intra-operative entrance of hydrogen peroxide through a suspected perforation of the orbital septum. The symptoms settled with conservative management.