Broadband absorbance in a liquid-core optical ring resonator

Thomas C Oates1, Lloyd W Burgess

  • 1Department of Chemistry, University of Washington, Seattle, Washington 98125-1700, USA. oatest@u.washington.edu

Applied Spectroscopy
|October 12, 2011
PubMed

Related Concept Videos

IR Absorption Frequency: Hybridization01:21

IR Absorption Frequency: Hybridization

Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
IR Absorption Frequency: Delocalization01:04

IR Absorption Frequency: Delocalization

Electron delocalization refers to the distribution of electrons across multiple atoms within a molecule rather than being confined to a single atom or bond. This phenomenon is common in systems with conjugated bonds—structures where alternating single and double bonds allow π-electrons to move freely across the network. The movement of electrons stabilizes the molecule and can affect various chemical properties, including vibrational frequencies observed in IR spectroscopy.
In IR spectroscopy,...
Characteristics of Series Resonant Circuit01:24

Characteristics of Series Resonant Circuit

Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Molecular Spectroscopy: Absorption and Emission01:14

Molecular Spectroscopy: Absorption and Emission

Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
UV–Vis Spectroscopy: Beer–Lambert Law01:09

UV–Vis Spectroscopy: Beer–Lambert Law

The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...