Correlation between jugular and central venous pressures in laterally recumbent horses
Karina Tam1, Marlis Rezende, Pedro Boscan
1Department of Clinical Sciences, Veterinary Teaching Hospital, Colorado State University, 300 W. Drake Road, Fort Collins, CO 80526, USA.
Objective:
To compare and correlate right atrial pressure, which represents central venous pressure (CVP) to jugular vein pressure (JVP) in laterally recumbent horses under anesthesia.
Study Design:
Retrospective clinical trial.
Animals:
Seven adult healthy horses (411 ± 8.7 kg).
Methods:
Horses were sedated with IV xylazine and anesthesia was obtained with IV ketamine and diazepam. Anesthesia was maintained with sevoflurane in oxygen. All horses were positioned in left lateral recumbency. An 8F catheter introducer was inserted into the right jugular vein to measure JVP. An 8F catheter introducer was inserted into the left jugular vein to be used as the port for a 7F 110 cm catheter that reached the right atrium to measure CVP. Both, CVP and JVP were measured simultaneously with a water calibrated aneroid manometer using the sternum as the 0 cmH(2) O reference point. Measurements were compared using Spearman correlation and the Bland-Altman plot.
Results:
Twenty paired samples were obtained over a period of 2 hours. The CVP ranged from 7 to 31 cmH(2) O, while the JVP ranged from 5 to 30 cmH(2) O. The Spearman correlation coefficient indicated that CVP and JVP had a strong correlation with r = 0.88. The Bland-Altman plot showed a bias of 0.7 cmH(2) O.
Conclusion And Clinical Relevance:
Jugular vein pressure showed a strong correlation with CVP in healthy, euvolemic, laterally recumbent anesthetized adult horses. Thus, JVP cannot replace CVP but it may be used clinically to monitor CVP in laterally recumbent horses.
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Assessing Blood pressure in the Leg
Preparation:
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: