Measurement and statistical analysis of single-molecule current-voltage characteristics, transition voltage

Shaoyin Guo1, Joshua Hihath, Ismael Díez-Pérez

  • 1Center for Bioelectronics and Biosensors, Biodesign Institute, and Department of Electrical Engineering, Arizona State University, Tempe, Arizona 85287, USA.

Related Concept Videos

Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
Voltammograms: Overview01:16

Voltammograms: Overview

Voltammograms are current plots as a function of applied potential, offering insights into electrochemical systems. The shape of a voltammogram depends on how the current is measured and whether convection (heat transfer by fluid movement) is present or absent.
Shapes of Voltammograms
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Metal-Semiconductor Junctions01:24

Metal-Semiconductor Junctions

The contact of metal and semiconductor can lead to the formation of a junction with either Schottky or Ohmic behavior.
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The semiconductor's...