Radiation exposure during endourologic procedures using over-the-table fluoroscopy sources
Related Experiment Video
Updated: May 28, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Manuel Ritter1, Patrick Krombach, Andreas Martinschek
1Department of Urology, University Medical Center Mannheim, Mannheim, Germany. manuel.ritter@umm.de
Background And Purpose:
Fluoroscopy is used daily by endourologic surgeons worldwide without knowledge of received radiation doses. We wanted to assess the radiation exposure of endourologic surgeons by frequently performed endourologic interventions with an over-the-table x-ray system.
Patients And Methods:
In this prospective single-center study, 235 endourologic interventions in 188 patients from April to September 2010 were included. Sixty-seven ureteral stent placements (USP), 51 ureteral stent changes (USC), 67 percutaneous stent changes (PSC), 11 percutaneous nephrolithotomies (PCNL), and 39 ureterorenoscopies (URS) were performed by 12 surgeons. The surgeon`s radiation exposure was measured with one thermoluminescent dosimeter (TLD) at the forehead and one at the ring finger. TLDs were analyzed at a central institute. The radiation dose detected at the forehead was counted as representative for the lens of the eye and the thyroid.
Results:
Mean patient age was 60.6 (± 18.8) years. Analysis of the TLD showed the following average values at the forehead for each intervention: USP and USC 0.04 mSv; PSC 0.03 mSv; PCNL 0.18 mSv; URS 0.1 mSv. Average finger values are: USP 0.13 mSv; USC 0.21 mSv; PSC 0.20 mSv; PCNL 4.36 mSv; URS 0.15 mSv.
Conclusions:
This report evaluates surgeons' radiation exposure by everyday endourologic interventions of different complexity. Most can be performed with an over-the-table x-ray system without exceeding statutory limits. Especially for PCNL, surgeons should consider possible protective action.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies III: Computed Tomography
Endoscopic Procedures V: ERCP
Patient...
Imaging Studies II: Ultrasonography
Imaging Studies VII: Vascular Imaging