Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Equilibrium partition coefficients of diverse polar and nonpolar organic compounds to polyoxymethylene (POM) passive
Satoshi Endo1, Sarah E Hale, Kai-Uwe Goss
1Department of Analytical Environmental Chemistry, UFZ-Helmholtz Centre for Environmental Research, Permoserstrasse 15, D-04318 Leipzig, Germany. satoshi.endo@ufz.de
Abstract:
Equilibrium passive samplers (EPS) based on polyoxymethylene (POM) are increasingly used for determining freely dissolved water and pore water concentrations of hydrophobic organic compounds in the environment. Unlike other polymeric materials commonly used as EPS, namely poly(dimethylsiloxane) (PDMS) and low-density polyethylene (PE), POM is a polar polymer, containing repeating H-bond accepting ether units. Thus, POM is expected to be a more sensitive EPS than PDMS and PE for polar, H-bond donating compounds, such as many hormones, pharmaceuticals, and biocides. To better characterize the sorption capacity of POM for diverse polar and apolar compounds, equilibrium POM-water partition coefficients, K(POM/w), were measured for 56 compounds, including several classes of polar compounds and organochlorine pesticides. Using this data set and literature data, various POM-partitioning models were calibrated and validated for their ability to predict K(POM/w). The best performing models tested were an Abraham descriptor based polyparameter linear free energy relationship (PP-LFER) (SD = 0.24 log units) and COSMOthermX (SD = 0.37 log units). The performance of SPARC (SD = 0.61 log units) and log-log correlations with K(ow) (SD = 0.49 log units) were lower. A comparison with PDMS and PE confirmed expectations that POM exhibits a higher sensitivity for H-bond donating polar compounds than PDMS and PE do for these compounds. These findings expand the domain of chemicals for which POM can be used as an EPS sampler, and demonstrate that POM is as suitable a passive sampler for many polar organic compounds as it is for hydrophobic organic compounds.
Related Concept Videos
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an organic...
Factors Affecting Dissolution: Drug pKa, Lipophilicity and GI pH
A drug's pKa and the pH of the gastrointestinal (GI) tract play crucial roles in drug...
Analyte Adsorption and Distribution
Determination of Molar Masses of Polymers II
Polymers: Molecular Weight Distribution
Molecular Shape and Polarity