Related Experiment Video
Updated: May 28, 2026

Nitropeptide Profiling and Identification Illustrated by Angiotensin II
Published on: June 16, 2019
Iodination on tyrosine residues during oxidation with sodium periodate in solid phase extraction of N-linked
Alejandro M Cohen1, Ripsik Kostyleva, Kenneth A Chisholm
1National Research Council, Institute for Marine Biosciences, 1411 Oxford St., Halifax, Nova Scotia, Canada.
Abstract:
Solid-phase extraction of N-linked glycopeptides (SPEG) using hydrazide-modified supports has become a common sample preparation procedure in glycoproteomic experiments. We demonstrate that iodination of tyrosine residues occur in SPEG as a side reaction during an oxidation step with sodium periodate. MS/MS analysis of oxidized bovine serum albumin and carbonic anhydrase digests revealed a characteristic shift of m/z 125.9 on all y and b fragment ions containing the modified tyrosine residues. Selected reaction monitoring (SRM) measurements showed that the peak intensity from of the iodinated peptides increased during the course of oxidation. After an hour of oxidation, SRM analysis revealed that the strongest signal from an iodinated peptide was approximately one-tenth of the intensity of the corresponding unmodified peptide. Iodinated tyrosine residues were also identified in serum samples subjected to SPEG and analyzed by LC-ESI-MS/MS. We recommend assessing this side reaction by including iodotyrosine as a variable modification when performing database searches on SPEG experiments. For SRM-based acquisitions, we encourage the avoidance of tyrosine-containing glycopeptides or, if this is not practical, monitoring transitions that contain the potential modified iodinated tyrosine residue to monitor the presence of the iodinated form of the glycopeptide.
More Related Videos
07:16Resin-Assisted Capture Coupled with Isobaric Tandem Mass Tag Labeling for Multiplexed Quantification of Protein Thiol Oxidation
Published on: June 21, 2021
07:38Enabling Real-Time Compensation in Fast Photochemical Oxidations of Proteins for the Determination of Protein Topography Changes
Published on: September 1, 2020
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Phase II Reactions: Sulfation and Conjugation with α-Amino Acids