Related Experiment Video
Updated: May 28, 2026

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
The use of transcutaneous thermal convection analysis to assess shunt function in the pediatric population
Arthur E Marlin1, Sarah J Gaskill
1Department of Neurosurgery and Brain Repair, Division of Pediatric Neurosurgery, University of South Florida, Tampa, Florida 33606, USA.
Background:
The diagnosis of shunt malfunction is largely made by subjective clinical history and assessment in association with neurodiagnostic imaging.
Objective:
: To evaluate the use of a transcutaneous thermal convection device for the diagnosis of shunt malfunction.
Methods:
We present the results of a trial of a commercially available device under an Institutional Review Board-approved protocol. All patients had neurodiagnostic studies that defined their shunt function at the time of transcutaneous thermal convection measurement. Thirty-seven shunts were studied in 35 patients. To be included, patients had to be between 0 to 18 years of age, had to be due within a 3-month period for routine follow-up evaluations, and had to have neurodiagnostic imaging (computed tomography or magnetic resonance imaging) as part of this visit and a shunt series. All patients were seen in routine follow-up, and none had clinical symptoms of shunt malfunction.
Results:
Three patients had fractured shunts. The remaining 32 patients had functioning shunts as determined by clinical criteria, computed tomography or magnetic resonance imaging scans, and, when appropriate, a shunt series. In these remaining patients, flow was initially confirmed in only 40%. After some filtering of the data, this was increased to 51%. Although these results are disappointing, they outline the current issues with the technique and the state of its utility and point to the need for further refinement.
Conclusion:
Our current research suggests that cerebrospinal fluid flow as detected by thermoconvection analysis is not a reliable indicator of shunt function in the pediatric population.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.