Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 28, 2026

3D Whole-heart Myocardial Tissue Analysis
06:53

3D Whole-heart Myocardial Tissue Analysis

Published on: April 12, 2017

Mitral Annulus Segmentation from Three-Dimensional Ultrasound.

Robert J Schneider1, Douglas P Perrin, Nikolay V Vasilyev

  • 1Harvard School of Engineering and Applied Sciences, Cambridge, MA, USA.

Proceedings. IEEE International Symposium on Biomedical Imaging
|October 21, 2011
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Tissue removal inside the beating heart using a robotically delivered metal MEMS tool.

The International journal of robotics research·2026
Same author

Annulus downsizing in valve-sparing aortic root replacement predicts aortic valve reoperation in children and young adults.

JTCVS open·2025
Same author

Novel size-adjustable pulmonary valve US early feasibility study: One-year outcomes.

The Journal of thoracic and cardiovascular surgery·2025
Same author

Atrioventricular Inflow and Subsequent Ventricular Growth After Staged Ventricular Recruitment for Unbalanced Atrioventricular Canal Defect.

The Annals of thoracic surgery·2025
Same author

Large scale causal modeling to identify adults at risk for combined and common variable immunodeficiencies.

NPJ digital medicine·2025
Same author

Image-based simulation of mitral valve dynamic closure including anisotropy.

Medical image analysis·2024

This article introduces a new computer-based method to automatically trace the shape of the mitral valve ring using 3D ultrasound images. By requiring only one starting point from a user, the system accurately maps the valve's structure, overcoming limitations found in older 2D-based approaches. This tool helps doctors diagnose heart conditions and create better models of valve function. Tests show the process is reliable and matches manual tracings performed by experts.

Area of Science:

  • Medical imaging research within cardiovascular medicine
  • Computational Mitral Annulus Segmentation techniques in biomedical engineering

Background:

Medical professionals often struggle to obtain precise measurements of heart valve structures using standard imaging techniques. Existing approaches frequently rely on two-dimensional data, which fails to capture the complex, non-planar geometry of the heart. This limitation leads to significant errors in spatial coherence during clinical assessments. No prior work had resolved the difficulty of maintaining anatomical accuracy across volumetric datasets. That uncertainty drove the need for more sophisticated computational tools. Researchers have long sought reliable ways to automate the identification of cardiac boundaries. This gap motivated the development of advanced algorithms capable of processing three-dimensional information. The current study addresses these challenges by proposing a novel framework for analyzing valve morphology.

Purpose Of The Study:

The aim of this study is to present an automated algorithm for tracing the mitral valve ring using volumetric data. Researchers sought to address the inaccuracies inherent in current two-dimensional segmentation methods. This project focuses on improving the spatial coherence of valve geometry during image processing. The authors intended to create a tool that simplifies the workflow for clinicians and scientists. By requiring only a single user-specified point, the team aimed to reduce the time and effort needed for manual analysis. This effort was motivated by the need for more reliable pathology diagnosis and valve modeling. The study explores how max-flow and active contour methods can be combined for better results. The primary goal remains the development of a robust system for three-dimensional ultrasound analysis.

Keywords:
cardiac imagingvolumetric analysiscomputational geometryechocardiography

Frequently Asked Questions

The researchers propose a method utilizing max-flow and active contour techniques. This approach requires only a single user-defined point near the valve center to initiate the automated delineation of the three-dimensional geometry.

The system employs max-flow optimization alongside active contour models. These components work together to ensure the boundary remains coherent in a volumetric space, unlike traditional two-dimensional methods which often lack depth information.

A single user-specified point near the center of the valve is necessary. This input acts as the starting seed, allowing the algorithm to correctly locate and trace the surrounding anatomical structure within the ultrasound volume.

The algorithm processes three-dimensional ultrasound data. This volumetric input allows the system to overcome the spatial inaccuracies inherent in two-dimensional imaging, providing a more comprehensive representation of the heart valve.

Related Experiment Videos

Last Updated: May 28, 2026

3D Whole-heart Myocardial Tissue Analysis
06:53

3D Whole-heart Myocardial Tissue Analysis

Published on: April 12, 2017

Main Methods:

The review approach involves evaluating a novel computational framework designed for volumetric cardiac data. Investigators utilized max-flow optimization to establish global boundaries within the image space. Active contour models were subsequently applied to refine the precise shape of the valve ring. The design relies on a solitary seed point provided by the operator to initiate the process. Researchers compared the automated outputs against standard manual tracings to validate performance. A sensitivity analysis tested the stability of the results under varying initial conditions. This methodology emphasizes the transition from planar analysis to full spatial reconstruction. The team focused on achieving high reproducibility across different datasets.

Main Results:

Key findings from the literature demonstrate that the algorithm achieves high accuracy in mapping the valve structure. The automated process successfully delineates the geometry in three-dimensional space with minimal user intervention. Comparisons to manual segmentations confirm that the system produces results consistent with expert interpretations. The sensitivity study reveals that the method maintains robustness despite minor variations in the starting input. These results highlight a significant improvement over traditional two-dimensional approaches that often suffer from spatial incoherence. The data suggests that the proposed technique effectively captures the complex shape of the valve. Performance metrics indicate that the tool is both reliable and efficient for clinical applications. The findings provide strong evidence for the utility of this computational approach in cardiac imaging.

Conclusions:

The proposed algorithm provides a reliable way to delineate the valve ring in three-dimensional space. Authors suggest that this method improves upon previous two-dimensional techniques by ensuring better spatial consistency. Results indicate that the automated approach achieves high accuracy when compared against manual tracing performed by experts. The researchers propose that this tool serves as a valuable asset for pathology diagnosis. Synthesis and implications suggest that the system remains robust even when user input varies slightly. Future clinical workflows may benefit from the efficiency gained through this automated process. The study demonstrates that volumetric data analysis enhances the precision of cardiac modeling. These findings confirm the potential for integrating advanced computational geometry into routine echocardiographic evaluations.

The researchers measured accuracy by comparing automated results to manual segmentations. They also performed a sensitivity study to evaluate how robust the algorithm remains when user inputs are slightly altered.

The authors claim that this method offers a more accurate and reproducible alternative to existing techniques. They propose that this improvement supports better pathology diagnosis and more precise modeling of cardiac valves.