Intravenous pyelogram artefacts unique to digital tomosynthesis reconstruction
1Clinical and Radiation Physics Department, Plymouth Hospitals NHS Trust, Derriford Road, Plymouth PL6 8DH, UK. ben.rowberry@phnt.swest.nhs.uk
Abstract:
Recent advances in technology have led to the realisation of digital tomosynthesis (DT) imaging in routine investigations such as intravenous pyelogram (IVP). The major advantage this technology has over other technologies is its ability to perform a retrospective reconstruction of an arbitrary number of coronal image planes from a single data set consisting of a series of low dose discrete projections acquired over a limited angular range using a stationary detector. It is well documented that because DT relies on an angular limited acquisition, the data set is incomplete. This, in combination with the image reconstruction algorithm, results in reconstructed images containing non-focused information from outside the immediate focal plane. This article describes and suggests the cause of two artefacts unique to DT that cannot be explained by blurring alone. We believe the two artefacts are caused by breathing during data acquisition together with a combination of other factors, including the anatomy of the renal system, the method of data acquisition and the reconstructive algorithm used. This could lead to the unaware reporting radiologist falsely diagnosing a duplex collecting system. To avoid these artefacts, we recommend DT IVP should only be used in patients who can adequately perform a breath-hold for the duration of the data acquisition. In addition, we suggest that the study should be performed with breath-held following expiration.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
05:41Synchronous Triplanar Reconstruction Integrated with Color Doppler Mapping for Precise and Rapid Localization of Thyroid Lesions
Published on: February 9, 2024
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies VII: Vascular Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies VI: Voiding Cystourethrography and Cystography