Reliability of video motion-analysis systems to measure amplitude and velocity of shoulder elevation
Christopher Melton1, David R Mullineaux, Carl G Mattacola
1University of Washington, Seattle, WA, USA.
Context:
Dynamic shoulder motion can be captured using video capture systems, but reliability has not yet been established.
Objective:
To compare the reliability of 2 systems in measuring dynamic shoulder kinematics during forward-elevation movements and to determine differences in these kinematics between healthy and injured subjects.
Design:
Reliability and cohort.
Setting:
Research laboratory.
Participants:
11 healthy subjects and 10 post-superior labrum anteroposterior lesion patients (SLAP).
Intervention:
Contrasting markers were placed at the hip, elbow, and shoulder to represent shoulder elevation and were videotaped in 2 dimensions. Subjects performed 6 repetitions of active elevation (AE) and active assisted elevation of the shoulder, and 3 trials were analyzed using Datapac (comprehensive system) and Dartfish (basic system).
Main Outcome Measures:
Amplitudes and velocities of the shoulder angle were calculated. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and levels of agreement (LOA) were used to determine intersystem and intertrial reliability.
Results:
For AE, the amplitude maximum (ICC = .98-.99, SEM = 2-3°, LOA = -9° to 5°) and average velocity (ICC = .94-.97, SEM = 1°/s, LOA = -4° to 1°/s) indicated excellent intersystem reliability between systems. Intratrial reliability for minimum velocity was moderate for Datapac (ICC = .64, SEM = 4°/s, LOA = 7°/s) and poor for Dartfish (ICC = .52, SEM = 20°/s, LOA = 37°/s). Cohort results demonstrated for AE a greater amplitude for healthy v SLAP (139° ± 11° v 113° ± 13°; P = .001) and interaction for an average velocity increase of 2°/s in healthy and decrease of 2°/s in SLAP patients over the 3 trials (P = .02).
Conclusions:
Reliability ranges provide the means to assess the clinical meaningfulness of results. The cohort differences are supported when the values exceed the ranges of the SEM; hence the amplitude results are meaningful. For dynamic shoulder elevation measured using video, the assessment of velocity was found to produce moderate to good reliability. The results suggest that with these measures subtle changes in both measures may be possible with further investigations.
Related Concept Videos
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the drone...