Related Experiment Video
Updated: May 28, 2026

Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
Application of artificial neural network to predict the retention time of drug metabolites in two-dimensional liquid
H Noorizadeh1, S Sobhan-Ardakani, F Raoofi
1Department of Chemistry, Ilam Branch, Islamic Azad University, Ilam, Iran. hadinoorizadeh@yahoo.com
Abstract:
Genetic algorithm and partial least square (GA-PLS) and Levenberg-Marquardt artificial neural network (L-M ANN) techniques were used to investigate the correlation between retention time and descriptors for drug metabolites which obtained by two-dimensional liquid chromatography. The applied internal (leave-group-out cross validation (LGO-CV)) and external (test set) validation methods were used for the predictive power of four models. Both methods resulted in accurate prediction whereas more accurate results were obtained by L-M ANN model. The best model obtained from L-M ANN showed a good R(2) value (determination coefficient between observed and predicted values) for all compounds, which was superior to GA-PLS models.
More Related Videos
07:502D-HPLC-MS Technology Combined with Molecular Network for the Identification of Components in Tibetan Medicine Aconitum pendulum
Published on: December 8, 2023
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Chromatographic Methods: Terminology
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: