Related Experiment Video
Updated: May 28, 2026

Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
Rapid determination of syringyl: guaiacyl ratios using FT-Raman spectroscopy
Lan Sun1, Patanjali Varanasi, Fan Yang
1Joint BioEnergy Institute, Physical Biosciences Division, Lawrence Berkeley National Laboratory, 5885 Hollis Street, Emeryville, California 94608, USA.
Abstract:
Lignin composition in relation to its basic phenylpropanoid units, particularly the syringyl to guaiacyl (S/G) ratio, is an important property for biomass characterization and varies greatly as a function of species, genotype and environment. A rapid screening method is highly desirable to assess lignin composition in a large number of samples. We have developed a nondestructive and label-free Fourier transform Raman (FT-Raman) spectroscopic method that is capable of rapidly and reliably measuring the S/G ratio with minimal sample preparation. A variety of feedstocks, including hardwood (Eucalyptus globulus), softwood (Pinus radiata), herbaceous plants (Zea mays, Panicum virgatum, and Sorghum bicolor), and a model dicot (Arabidopsis thaliana) were measured using this technique and the corresponding S/G ratio was calculated after spectral deconvolution based on the S and G bands identified using a known library of model compounds. The results obtained using this technique were successfully validated by pyrolysis-gas chromatography/mass spectrometry (pyro-GC/MS). This technique holds significant promise in the rapid screening of engineered feedstocks as part of a comprehensive screening methodology that is correlated with biomass recalcitrance.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Spectroscopy of Carboxylic Acid Derivatives
In the...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
NMR Spectroscopy of Aromatic Compounds

