Related Experiment Video
Updated: May 28, 2026

In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
Doping control of biosimilar epoetin kappa and other recombinant erythropoietins after intravenous application
Masato Okano1, Mitsuhiko Sato, Emi Kaneko
1Anti-Doping Laboratory, Mitsubishi Chemical Medience Corporation, Tokyo, Japan. Okano.Masato@mk.medience.co.jp
Abstract:
Since the expiration of patent protection, a number of new recombinant erythropoietin (rEPO) biosimilars have appeared on the worldwide market. In 2010, epoetin kappa, which is biosimilar to epoetin alfa, was clinically approved in Japan. Currently, both isoelectric focusing polyacrylamide gel electrophoresis (IEF-PAGE) and sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) are approved by the World Anti-Doping Agency (WADA) for detection of rEPO doping. Because it was unclear whether epoetin kappa could be detected by WADA-accredited detection methods, intravenous administration studies of epoetin kappa, epoetin alfa, and epoetin beta were performed to test the applicability of these methods. The isoform bands of epoetin kappa expanded more widely towards the basic area and the profile appeared to be composed of at least eight bands, which were clearly different from those of other epoetins. The results showed that epoetin kappa also contains isoforms of higher molecular masses than those of originator epoetins on SDS-PAGE; the mass distribution was confirmed by electrospray ionization time-of-flight mass spectrometry. We clearly detected epoetin kappa after its administration up to 10 h by IEF-PAGE and 24 h by SDS-PAGE; the detection window of the SDS-PAGE is longer than that of the IEF-PAGE. SDS-PAGE compensates for the disadvantages of IEF-PAGE in detecting urinary epoetin kappa. We also concluded that athletes abusing rEPO might move to intravenous injections for shorter clearance times instead of subcutaneous injections. In conclusion, out-of-competition tests need to be applied more frequently to improve the effectiveness of the rEPO detection.
More Related Videos
11:59Detection of Residual Donor Erythroid Progenitor Cells after Hematopoietic Stem Cell Transplantation for Patients with Hemoglobinopathies
Published on: September 6, 2017
06:37Using Reference Reagents to Confirm Robustness of Cytokine Release Assays for the Prediction of Monoclonal Antibody Safety
Published on: September 15, 2023
Related Concept Videos
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Drug Products: Biologics, Biosimilars and Interchangeables
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration