Related Experiment Video
Updated: May 28, 2026

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
In utero release of constriction amniotic bands via blunt dissection
Raymen Assaf1, Arlyn Llanes, Ramen Chmait
1Department of Obstetrics and Gynecology, University of Southern California, Keck School of Medicine, Los Angeles, California 90027, USA.
Abstract:
Therapeutic techniques for in utero release of amniotic bands have relied on transecting instruments. We present an additional technique, blunt dissection, to release a constriction band in utero. The lower extremity that had detectable abnormalities during prenatal ultrasound had improved outcome after blunt in utero release of the amniotic band compared to the contralateral (control) leg. These findings support two conjectures: first, the degree of band adherence to the fetus is an important factor influencing the surgical approach to in utero lysis of the bands; second, that in utero release of constriction bands can result in improvement in outcome.