Related Experiment Video
Updated: May 28, 2026

Preparation and Use of Photocatalytically Active Segmented Ag|ZnO and Coaxial TiO2-Ag Nanowires Made by Templated Electrodeposition
Published on: May 2, 2014
Trace detection of dissolved hydrogen gas in oil using a palladium nanowire array
Fan Yang1, Dongoh Jung, Reginald M Penner
1Department of Chemistry, University of California, Irvine, California 92697-2025, United States.
Abstract:
The electrical resistance, R, of an array of 30 palladium nanowires is used to detect the concentration of dissolved hydrogen gas (H(2)) in transformer oil over the temperature range from 21 to 70 °C. The palladium nanowire array (PdNWA), consisting of Pd nanowires ∼100 nm (width), ∼20 nm (height), and 100 μm (length), was prepared using the lithographically patterned nanowire electrodeposition (LPNE) method. The R of the PdNWA increased by up to 8% upon exposure to dissolved H(2) at concentrations above 1.0 ppm and up to 2940 ppm at 21 °C. The measured limit-of-detection for dissolved H(2) was 1.0 ppm at 21 °C and 1.6 ppm at 70 °C. The increase in resistance induced by exposure to H(2) was linear with [H(2)](oil)(1/2) across this concentration range. A PdNWA sensor operating in flowing transformer oil has functioned continuously for 150 days.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...